-40%

Dell PowerConnect 8164F 48-Port 10GbE SFP+ 2xQSFP+ Network Switch VTWN8+PHP6T

$ 369.59

Availability: 100 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Type: Ethernet Switch
  • Brand: Dell
  • Return shipping will be paid by: Seller
  • MPN: 0VTWN8/VTWN8
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • Item must be returned within: 30 Days
  • Model: PowerConnect 8164F
  • Condition: This is a USED WORKING item in GOOD cosmetic condition that IS THOROUGHLY TESTED and is GUARANTEED WORKING

    Description

    TESTING & COSMETIC NOTES:
    This is a USED WORKING item in GOOD cosmetic condition that IS THOROUGHLY TESTED and is GUARANTEED WORKING
    This unit has been factory reset, view console log for more info.
    COMPONENTS INCLUDED IN THIS AUCTION:
    • (1) - DELL POWERCONNECT 8164F 48-PORT 10GBE SFP+ 2XQSFP+ NETWORK SWITCH 0VTWN8 VTWN8
    • (1) - DELL POWERCONNECT PC8100 4-PORT 10GSFP+ 10GBASE-T QUAD-PORT NETWORK MODULE PHP6J
    • (2) - DELL DELTA DPS-460KB-C 460W POWER SUPPLY 0XN7P4 XN7P4
    • (1) - SLIDING RAIL SET
    • (2) - POWER CORD
    REPLACEMENT or MONEY BACK GUARANTEE:
    When you receive a Guaranteed item from OC Depot, it should perform as described. In the rare situation that this is not the case, we will send a replacement upon safe return of the original item within 30 days of receiving the item. If a replacement is not available we will honor the terms of our Money-Back Guarantee.
    ADDITIONAL INFORMATION:
    The following is the Console Log from this item:
    U-Boot 2010.03-rc1 (Jul 13 2012 - 08:44:21)
    DRAM: 2 GB
    Initialized CPLD on CS3
    Detected [XLP308 (Lite+) Rev A1]
    Initializing I2C0: speed = 48 KHz -- done.
    Initializing I2C1: speed = 48 KHz -- done.
    Now running in RAM - U-Boot [N64 ABI, Big-Endian] at: ffffffff8c100000
    Flash: 256 MB
    PCIE (B0:D01:F0) : Link up.
    PCIE (B0:D01:F1) : No Link.
    In: serial
    Out: serial
    Err: serial
    OOB MAC addr = d0:67:e5:a7:ac:9b
    XLP3XX FMN configuration
    POE ext msg storage:
    POE Free Buffer Pool config ...
    Net: Successfully zapped free in fifo!
    Configuring ucore...
    Loading ucores (mask = 0x00ff)
    Configuring NAE...
    NAE Frequency set to 499MHz (2X frequency 999MHz)
    num-ports = 1, start-port-id = 0
    Scanning MDIO external BUS0----
    Found port with 0th bus and phy_addr =0x1 phy-idfer=0x3625d12
    Total PHYs found = 1
    xlp_nae_config_lane_gmac with cplx_mask=0x1 and config=0x1111
    Net: Completed PCS Configuration
    fdt missing num-lanes, default 4
    nlm_hal_ilk_pcs_init ilk_cplx_mask 0x0
    parse_fdt_nae_config Completed NETIOR soft reset
    Warning: Len is 0 while copying /soc/nae-cfg/port@0/intf-regs
    Configuring per-port interface registers for port@0
    Configuring per-port NAE registers for port@0
    nlm_hal_open_if: 0CLEARING speed bit =0x2
    Initializing OOB Ethernet PHY:
    Starting auto-negotiation on port 0, external mdio bus 0, phy address 1
    Unknown operating speed
    Configured with Speed 10Mb HDX
    Link is down
    Storm:Initialized port@0
    Configuring CPU-NAE...
    Configuring PoE...
    Configuring POE in bypass mode
    NAE configuration done!
    Digest of FDT based NAE config:
    nae-0: PHY is Broadcom BCM54616S (3625d12)
    nae-0
    Hit any key to stop autoboot: 0
    Booting image at /dev/mtd7....
    ## Booting kernel from Legacy Image at 9000000096000074 ...
    Image Name: System for pct
    Created: 2013-10-14 18:33:08 UTC
    Image Type: MIPS Linux Multi-File Image (gzip compressed)
    Data Size: 16153970 Bytes = 15.4 MB
    Load Address: ffffffff84000000
    Entry Point: ffffffff84006330
    Contents:
    Image 0: 2642366 Bytes = 2.5 MB
    Image 1: 1276225 Bytes = 1.2 MB
    Image 2: 8391 Bytes = 8.2 kB
    Image 3: 474 Bytes = 0.5 kB
    Image 4: 12226482 Bytes = 11.7 MB
    Verifying Checksum ... OK
    ## Loading init Ramdisk from multi component Legacy Image at 9000000096000074 ..
    .
    Copying the root file system to 0xffffffff81000000... OK
    ## Flattened Device Tree from multi component Image at 9000000096000074
    Booting using the fdt at 0x963bcbd0
    Uncompressing Multi-File Image ... OK
    Starting kernel ...
    Linux version 2.6.27.47 (steveu@lc-rtp-000) (gcc version 4.3.2 (Wind River Linux
    Toolchain 4.3a-287 - User Built) ) #1 SMP PREEMPT Thu May 9 09:11:22 EDT 2013
    Enabling XLP CPU (XLP308 Rev A1)
    Cached handle for FDT @ 90000000963bcbd0
    FDT Cmdline: loader=uboot console=ttyS0,9600 quiet root=/dev/ram console=ttyS0,9
    600 disable_etlb disable_128tlb disable_pgwalker mem=176m@16m mem=1536m@512m
    FDT: cpu_cells: 1 onlinemask[0]: 00000011
    fdt_cpumask: 00000011
    node@0: t0_bitmap = 0x00000011, cores_bitmap = 0x00000003
    [enable_cores] node@0, cores_bitmap = 0x00000003 cbitmap = 0x00000002
    Enabled cpus (0x00000011) on node@0
    console [early0] enabled
    CPU revision is: 000c1101 (XLP)
    FPU revision is: 00770000
    Checking for the multiply/shift bug... no.
    Checking for the daddiu bug... no.
    [pcibios_init]: IO-Remapped phys=14000000, size=2000000 to vaddr=900000001400000
    starting pid 914, tty '': '/etc/init.d/rcS'
    starting pid 920, tty '/dev/ttyS0': '/etc/rc.d/rc.fastpath'
    Mounting /dev/mtdblock5 at /mnt/fastpath...done.
    Mounting tmpfs at /mnt/application...done.
    Checking for USB Device... done.
    No USB Device found!
    Boot Menu Rev: 5.0
    Select startup option within 5 seconds, else Operational Code will start automat
    ically...
    Operational Code Startup -- Main Menu
    1 - Start Operational Code
    2 - Display Boot Menu
    Select (1, 2)#
    active = /dev/mtd7
    Extracting Operational Code from .stk file...done.
    Loading Operational Code...done.
    Decompressing Operational Code...done.
    Scanning devshell symbols file...
    47578 symbols, loading...
    Done.
    PCI unit 0: Dev 0xb846, Rev 0x02, Chip BCM56846_A0, Driver BCM56840_B0
    SOC unit 0 attached to PCI device BCM56846_A0
    Adding BCM transport pointers
    Configuring CPUTRANS TX
    Configuring CPUTRANS RX
    hpc - No stack ports. Starting in stand-alone mode.
    <186> Jul 13 23:28:40 0.0.0.0-1 General[72064036]: bootos.c(166) 2 %% Event(0xaa
    aaaaaa)
    started!
    (Unit 1 - Waiting to select management unit)>
    Applying Global configuration, please wait ...
    Welcome to Dell Easy Setup Wizard
    The setup wizard guides you through the initial switch configuration, and
    gets you up and running as quickly as possible. You can skip the setup
    wizard, and enter CLI mode to manually configure the switch. You must
    respond to the next question to run the setup wizard within 60 seconds,
    otherwise the system will continue with normal operation using the default
    system configuration. Note: You can exit the setup wizard at any point
    by entering [ctrl+z].
    Would you like to run the setup wizard (you must answer this question within
    60 seconds)? [Y/N] n
    Thank you for using the Dell Easy Setup Wizard. You will now enter CLI mode.
    Applying Interface configuration, please wait ...
    console>en
    console#show ver
    System Description................ Dell Ethernet Switch
    System Up Time.................... 0 days, 00h:01m:44s
    System Contact....................
    System Name.......................
    System Location...................
    Burned In MAC Address............. D067.E5A7.AC9A
    System Object ID.................. 1.3.6.1.4.1.674.10895.3046
    System Model ID................... PCT8164F
    Machine Type...................... PowerConnect 8164F
    CPU Version....................... XLP308H-A1
    unit active backup current-active next-active
    ---- ----------- ----------- -------------- --------------
    1 5.1.2.3 5.0.0.4 5.1.2.3 5.1.2.3
    console#show system
    System Description: Dell Ethernet Switch
    System Up Time: 0 days, 00h:01m:55s
    System Contact:
    System Name:
    System Location:
    Burned In MAC Address: D067.E5A7.AC9A
    System Object ID: 1.3.6.1.4.1.674.10895.3046
    System Model ID: PCT8164F
    Machine Type: PowerConnect 8164F
    Temperature Sensors:
    Unit Description Temperature Status
    (Celsius)
    ---- ----------- ----------- ------
    1 MAC 33 Good
    1 CPU 34 Good
    1 PHY (left side) 30 Good
    1 PHY (right side) 31 Good
    Fans:
    Unit Description Status
    --More-- or (q)uit
    ---- ----------- ------
    1 Fan 1 OK
    1 Fan 2 OK
    1 Fan 3 OK
    1 Fan 4 OK
    1 Fan 5 OK
    1 Fan 6 OK
    Power Supplies:
    Unit Description Status Average Current Since
    Power Power Date/Time
    (Watts) (Watts)
    ---- ----------- ----------- ---------- -------- -------------------
    1 System OK 97.8 97.8
    1 Internal(R) OK N/A N/A 07/13/2021 23:28:54
    1 Internal(L) OK N/A N/A 07/13/2021 23:28:54
    USB Port Power Status:
    ----------------------
    Device Not Present
    console#
    Please Click Here to Visit Our Store
    SearchBy12 -
    231140
    | Loc: ZJACK | L: Jack | T:
    | PM: Nick
    | QTY: 0 | Plan: 50/50 NET of FEES | 24.00"x21.00"x5.00" 38.00lbs | Start: 9.99 | BIN: {{detail_product_description}}.00 |  | 7/15/2021 |
    |
    51268